智能化社區(qū)智能化系統(tǒng)安裝調(diào)試工程方案···································· 1
目 錄·························································································· 1
一章、工程概況················································································ 7
一、工程簡(jiǎn)介················································································· 7
三、工程目標(biāo)················································································· 8
第二章、組織機(jī)構(gòu)············································································ 9
三、項(xiàng)目管理工程系統(tǒng)組織機(jī)構(gòu)················································· 10
四、工程主要成員介紹································································ 11
五、主要人員簡(jiǎn)介········································································ 12
第四章、施工進(jìn)度及工期安排的保證·········································· 12
一、工期目標(biāo)··············································································· 12
二、工程進(jìn)度表(后附進(jìn)度計(jì)劃表)········································· 13
四、圖紙會(huì)審··············································································· 13
五、施工裝備階段········································································ 13
六、配合施工··············································································· 15
七、弱電工程施工階段································································ 15
八、與土建及機(jī)電設(shè)備安裝的協(xié)調(diào)及成品保護(hù)·························· 17
第五章、施工布置·········································································· 18
第六章、施工管線(xiàn)敷設(shè)要求·························································· 19
第七章、施工安裝工作程序·························································· 21
第八章、質(zhì)量保證體系和質(zhì)量保證計(jì)劃······································ 22
一、總則······················································································· 22
二、質(zhì)量管理體制········································································ 22
三、施工質(zhì)量管理········································································ 24
四、質(zhì)量保修··············································································· 25
五、調(diào)試前檢查··········································································· 25
六、系統(tǒng)調(diào)試··············································································· 26
第九章、工程交付與驗(yàn)收······························································ 27
第十章、健康、安全和文明施工·················································· 28
一、目標(biāo)······················································································· 28
二、職責(zé)······················································································· 28
三、健康安全文明的管理···························································· 28
第十一章、物資供應(yīng)及管理·························································· 32
一、目的······················································································· 32
二、物資供應(yīng)工作流程································································ 32
三、計(jì)劃編程··············································································· 32
四、采購(gòu)······················································································· 33
五、入庫(kù)······················································································· 33
六、物資發(fā)料··············································································· 34
七、物資的保管與保養(yǎng)································································ 35
八、物資盤(pán)點(diǎn)··············································································· 35
第十三章、智能弱電系統(tǒng)工程對(duì)土建專(zhuān)業(yè)要求·························· 37
二、甲方支持配合協(xié)調(diào)的工作····················································· 37
第二部分 主要施工方案···························································· 38
第一章、安防報(bào)警系統(tǒng)·································································· 38
一、系統(tǒng)概述··············································································· 38
二、功能簡(jiǎn)介··············································································· 38
三、管線(xiàn)敷設(shè)··············································································· 39
四、設(shè)備安裝··············································································· 39
第二章、閉路電視監(jiān)控系統(tǒng)·························································· 41
一、系統(tǒng)概述··············································································· 41
二、電源供應(yīng)方案········································································ 41
三、管線(xiàn)敷設(shè)··············································································· 42
四、設(shè)備安裝··············································································· 42
第三章、可視對(duì)講系統(tǒng)·································································· 43
一、系統(tǒng)概述··············································································· 43
二、功能簡(jiǎn)介··············································································· 43
三、管線(xiàn)敷設(shè)··············································································· 43
四、設(shè)備安裝··············································································· 44
第四章、周邊防范系統(tǒng)·································································· 45
一、系統(tǒng)概述··············································································· 45
二、功能簡(jiǎn)介··············································································· 45
三、管線(xiàn)敷設(shè)··············································································· 45
四、設(shè)備安裝··············································································· 46
第五章、巡更系統(tǒng)·········································································· 47
一、系統(tǒng)概述··············································································· 47
二、功能簡(jiǎn)介··············································································· 47
三、設(shè)備安裝··············································································· 47
第六章、公共設(shè)備控制系統(tǒng)·························································· 48
一、系統(tǒng)概述··············································································· 48
二、管線(xiàn)敷設(shè)··············································································· 48
第七章、門(mén)禁管理系統(tǒng)·································································· 49
一、系統(tǒng)概述··············································································· 49
二、系統(tǒng)功能··············································································· 49
三、管線(xiàn)敷設(shè)··············································································· 50
四、設(shè)備安裝··············································································· 50
第八章、停車(chē)場(chǎng)管理系統(tǒng)······························································ 51
一、系統(tǒng)概述··············································································· 51
二、系統(tǒng)功能··············································································· 51
三、管線(xiàn)敷設(shè)··············································································· 51
四、設(shè)備安裝··············································································· 52
第九章、背景音樂(lè)系統(tǒng)·································································· 53
一、系統(tǒng)概述··············································································· 53
二、功能簡(jiǎn)介··············································································· 53
三、管線(xiàn)敷設(shè)··············································································· 53
四、設(shè)備安裝··············································································· 54
第十章、LED電子公告顯示系統(tǒng)················································· 55
一、系統(tǒng)概述··············································································· 55
二、系統(tǒng)功能··············································································· 55
三、管線(xiàn)敷設(shè)··············································································· 56
四、設(shè)備安裝··············································································· 56
第十一章、中心機(jī)房······································································ 57
工程名稱(chēng):“****社區(qū)”弱電智能化工程
建設(shè)單位:****建設(shè)有限公司
工程地點(diǎn):
工程內(nèi)容:小區(qū)智能化系統(tǒng)施工、安裝、調(diào)試
施工單位:******科技實(shí)業(yè)有限公司
工程概述:本工程為****社區(qū)智能化系統(tǒng)設(shè)備供應(yīng)及安裝調(diào)試工程,主要系統(tǒng)如下:
1. 住宅安防報(bào)警系統(tǒng)
2. 閉路電視監(jiān)控系統(tǒng)
3. 周界防越系統(tǒng)
4. 家居安防報(bào)警系統(tǒng)
5. 可視對(duì)講管理系統(tǒng)
6. 電子巡更系統(tǒng)
7. 設(shè)備監(jiān)控系統(tǒng)
8. 智慧卡(門(mén)禁)管理系統(tǒng)
9. 地下車(chē)庫(kù)車(chē)輛管理系統(tǒng)
10. 小區(qū)背景音樂(lè)系統(tǒng)
11. 小區(qū)電子公告顯示系統(tǒng)
12. 小區(qū)綜合物業(yè)管理系統(tǒng)和綜合服務(wù)信息管理系統(tǒng)
13. 系統(tǒng)聯(lián)網(wǎng)及中心機(jī)房
計(jì)劃開(kāi)工日期: 按合同規(guī)定(監(jiān)理、甲方開(kāi)工通知為準(zhǔn))
智能化管理系統(tǒng)工程量大,區(qū)域范圍廣,各系統(tǒng)之間相互穿插,施工
難度大,要求嚴(yán)格,技術(shù)性強(qiáng),既要對(duì)其他系統(tǒng)具有保護(hù)意識(shí)又要保證本系統(tǒng)的可靠性以及整個(gè)系統(tǒng)的兼容與擴(kuò)展性,使之建成后符合國(guó)家智能化樓宇相關(guān)規(guī)范。
為使整個(gè)工程項(xiàng)目順利完成,對(duì)我們所提出的施工圖,積極做好跟
蹤服務(wù)工作,確保新埋管點(diǎn)位正確。本施工組織實(shí)施方案經(jīng)過(guò)綜合考慮,加強(qiáng)施工管理效能,合理組織,責(zé)任到人,人員到位,使工程施工安全、質(zhì)量、工期達(dá)到如期目標(biāo)。
施工安全:杜絕重大或大的責(zé)任事故,避免小事故發(fā)生。
施工質(zhì)量:嚴(yán)格按照施工規(guī)范、設(shè)計(jì)要求進(jìn)行、檢測(cè)標(biāo)準(zhǔn),確保每個(gè)工序一次性完成,力創(chuàng)“優(yōu)質(zhì)”工程。把****建成智能化小區(qū)之典范。
公司:“****”智能化系統(tǒng)工程管理---公司指揮部
現(xiàn)場(chǎng):“****”智能化系統(tǒng)工程----項(xiàng)目經(jīng)理部
l 項(xiàng)目經(jīng)理部:是在本工程中派出的負(fù)責(zé)項(xiàng)目施工全過(guò)程管理的唯一組織機(jī)構(gòu);項(xiàng)目經(jīng)理部嚴(yán)格實(shí)行項(xiàng)目法管理;在公司總體領(lǐng)導(dǎo)下,全面負(fù)責(zé)項(xiàng)目的施工管理,組織高效精干的隊(duì)伍,運(yùn)用“矩陣體制、動(dòng)態(tài)管理、目標(biāo)控制、節(jié)點(diǎn)考核”的項(xiàng)目動(dòng)態(tài)管理組織施工,實(shí)施工期、質(zhì)量、成本、安全四大控制,保證切實(shí)履行工程合同。
l 公司指揮部:其職能部門(mén)按制度定期到現(xiàn)場(chǎng)檢查、督促、指導(dǎo)項(xiàng)目部各項(xiàng)工作。
l 項(xiàng)目經(jīng)理部安全管理:設(shè)立項(xiàng)目安全員,在項(xiàng)目經(jīng)理的領(lǐng)導(dǎo)下,全面負(fù)責(zé)施工現(xiàn)場(chǎng)的安全工作,制定安全生產(chǎn)計(jì)劃、組建安全保證體系。
l 項(xiàng)目經(jīng)理部的質(zhì)量管理:設(shè)立項(xiàng)目質(zhì)量員,在項(xiàng)目經(jīng)理的領(lǐng)導(dǎo)下,負(fù)責(zé)組建項(xiàng)目經(jīng)理部質(zhì)保體系和領(lǐng)導(dǎo)項(xiàng)目經(jīng)理部質(zhì)保體系的日常工作,就項(xiàng)目施工質(zhì)量向公司管理者代表負(fù)責(zé)。
l 項(xiàng)目經(jīng)理部的技術(shù)管理:實(shí)行項(xiàng)目系統(tǒng)總工程師負(fù)責(zé)制,系統(tǒng)總工程師就技術(shù)工作對(duì)項(xiàng)目經(jīng)理負(fù)責(zé),設(shè)置責(zé)任工程師和系統(tǒng)施工員,形成自上而下的完善體系。
公司指揮部 |
|
|
|
|
|
|
1、公司、項(xiàng)目部管理人員
職務(wù)崗位 | 姓名 | 學(xué)歷 | 職務(wù) | 職稱(chēng) |
工程總指揮 | 大專(zhuān) | 總經(jīng)理 | 工程師 | |
工程技術(shù)總監(jiān) | 本科 | 總工程師 | 工程師 | |
項(xiàng)目經(jīng)理 | 本科 | 工程師 | 工程師 | |
系統(tǒng)工程師 | 本科 | 研發(fā)部經(jīng)理 | 工程師 | |
軟件工程師 | 本科 | 工程師 | ||
安全員、質(zhì)檢員 | 大專(zhuān) | 工程師 | ||
材料員 | 大專(zhuān) | 助理工程師 | ||
資料員 | 大專(zhuān) | 助理工程師 |
2、施工人員:
施工隊(duì)長(zhǎng):
班組成員: 管線(xiàn)班:(班長(zhǎng))
組員:
設(shè)備安裝班:(班長(zhǎng))
組員:
調(diào)試、運(yùn)行班:
班組人員根據(jù)工程實(shí)際情況合理調(diào)配。
***:工程師
(1)簡(jiǎn)單工作經(jīng)歷
(2)項(xiàng)目經(jīng)理,負(fù)責(zé)以下項(xiàng)目:
A 、大廈弱電系統(tǒng)(500萬(wàn));
B 、大廈(180萬(wàn));
C 、安防工程(350萬(wàn));
(3)項(xiàng)目經(jīng)理、部門(mén)負(fù)責(zé)人。
***:項(xiàng)目經(jīng)理
。。。
***:項(xiàng)目經(jīng)理
。。。
我們追求的進(jìn)度的目標(biāo)是:
在保證安裝和質(zhì)量的前提下,以甲方書(shū)面開(kāi)工通知起,施工工期內(nèi)全部完成本工程項(xiàng)目各系統(tǒng)的設(shè)備報(bào)驗(yàn)及工序報(bào)驗(yàn),以及線(xiàn)路測(cè)試、安裝、調(diào)試、驗(yàn)收及培訓(xùn)等工作。
說(shuō)明:進(jìn)度計(jì)劃將根據(jù)總工期要求,在實(shí)際施工過(guò)程中需與土建進(jìn)行配合、協(xié)調(diào)。開(kāi)工日期以監(jiān)理、甲方批準(zhǔn)的開(kāi)工報(bào)告為準(zhǔn)。
在正式簽約后,業(yè)主提供所有的平面圖,我們將會(huì)同業(yè)主、設(shè)計(jì)院澄清所有圖紙的問(wèn)題,然后針對(duì)圖紙中的問(wèn)題與業(yè)主、設(shè)計(jì)院進(jìn)行溝通,以解決圖紙中的問(wèn)題。由設(shè)計(jì)院更改好,經(jīng)業(yè)主下發(fā)我公司。此圖紙所設(shè)計(jì)的內(nèi)容為施工圖,并符合中華人民共和國(guó)國(guó)家標(biāo)準(zhǔn)和有關(guān)規(guī)范,在施工完成后,根據(jù)施工過(guò)程中所作的修改,我公司完成最后的竣工圖交業(yè)主存檔。
圖紙會(huì)審工作是一項(xiàng)極其嚴(yán)肅和重要的技術(shù)工作,認(rèn)真做好圖紙會(huì)審工作會(huì)減少施工圖中的差錯(cuò),保證和提高工程質(zhì)量有著重要作用,在圖紙會(huì)審前,我們將組織以前做過(guò)相應(yīng)工程的人員認(rèn)真閱讀施工圖,熟悉圖紙并做好技術(shù)交底工作,在安裝工程開(kāi)始前,把疑難問(wèn)題在圖紙會(huì)審中解決。
圖紙會(huì)審應(yīng)有組織、有領(lǐng)導(dǎo)、有步驟地進(jìn)行,會(huì)審結(jié)果應(yīng)形成記要,作為補(bǔ)充技術(shù)文件。
1、堅(jiān)持質(zhì)量第一,確保安全施工,在施工裝備階段我們根據(jù)合同、施工工期、進(jìn)度安排,成立與之適用的弱電安裝組織機(jī)構(gòu),配備工程所需技術(shù)力量及施工力量,組織施工人員熟悉學(xué)習(xí)工程建設(shè)施工圖各項(xiàng)資料,組織培訓(xùn)工程施工中的新技術(shù),新的施工方法、新工藝,組織施工人員熟悉各系統(tǒng)技術(shù)關(guān)鍵點(diǎn),教育職工在施工中認(rèn)真負(fù)責(zé),精心施工,創(chuàng)造一流的設(shè)備、一流的設(shè)計(jì)、一流的安裝。
2、嚴(yán)格執(zhí)行基本建設(shè)程序,在現(xiàn)階段弱電工程安裝施工驗(yàn)收規(guī)范不健全的情況下,我們將參照《電氣裝置安裝工程施工及驗(yàn)收規(guī)范》、《自動(dòng)化儀表工程施工及驗(yàn)收規(guī)范》、《建筑電氣安全工程質(zhì)量檢驗(yàn)、評(píng)定標(biāo)準(zhǔn)》、《自動(dòng)化儀表工程質(zhì)量檢驗(yàn)、評(píng)定標(biāo)準(zhǔn)》中有關(guān)相近的部分,使系統(tǒng)能夠可靠運(yùn)行。
3、根據(jù)合同及總工期要求在施工準(zhǔn)備階段還將作好以下工作:
☆ 協(xié)調(diào)好監(jiān)理、甲方關(guān)系,取得在工作上的支持使之具備完善施工條件。
☆ 編排好實(shí)用可行的施工進(jìn)度控制表。
☆ 施工工期具體保證措施。
☆ 勞動(dòng)力需求計(jì)劃表。
☆ 進(jìn)口、國(guó)產(chǎn)材料設(shè)備需求計(jì)劃表。
☆ 施工用機(jī)具、設(shè)備檢測(cè)儀器需求計(jì)劃表。
☆ 質(zhì)量、安全保證措施。
☆ 根據(jù)工程需要和現(xiàn)場(chǎng)實(shí)際情況,編制設(shè)備材料進(jìn)場(chǎng)計(jì)劃,適時(shí)到場(chǎng),確保進(jìn)度。
建筑工程的施工是比較復(fù)雜的,是各種專(zhuān)業(yè)空間交叉作業(yè)過(guò)程。
它主要包括土建、裝修、給排水、采暖通風(fēng)、電氣安裝等專(zhuān)業(yè)的施工。在施工中,如果某一專(zhuān)業(yè)只考慮本工種的施工,勢(shì)必影響其它工種的施工。建筑弱電施工是整個(gè)建筑工程的一個(gè)組成部分,與其它各專(zhuān)業(yè)的施工必然發(fā)生多方面的交叉作業(yè),各施工專(zhuān)業(yè)間的相互協(xié)調(diào)配合,在粉刷前需確保管路暢通,以便穿線(xiàn)。吊頂前所有線(xiàn)路穿好,并完成 底合、底板等固定工作,能夠使弱電裝置安裝得整潔美觀。
在工程進(jìn)行到一定階段,弱電安裝條件具備后,根據(jù)計(jì)劃安排施工。根據(jù)電氣專(zhuān)業(yè)有關(guān)質(zhì)量標(biāo)準(zhǔn)、規(guī)范、以及弱電專(zhuān)業(yè)的特殊要求,對(duì)電氣配管、支架、線(xiàn)槽、弱電箱、導(dǎo)線(xiàn)敷設(shè)、編號(hào)、接線(xiàn)等,從第一道工序開(kāi)始,要求施工人員、質(zhì)量員嚴(yán)格把關(guān),防止安裝上的質(zhì)量通病發(fā)生,發(fā)生后立即整改,否則不允許下道工序施工。質(zhì)量員對(duì)每道工序的檢查提出具體的技術(shù)措施、施工程序、檢驗(yàn)方法和記錄要求,對(duì)工序?qū)嵭?/span>“三檢制”,上道工序不合格,不準(zhǔn)轉(zhuǎn)到下道工序施工,保證每道工序都在控制之中。
在施工中,最主要的是各系統(tǒng)之間的聯(lián)系、配合,還要與強(qiáng)電、水系統(tǒng)、通風(fēng)系統(tǒng)、設(shè)備各專(zhuān)業(yè)之間協(xié)作,對(duì)影響進(jìn)度的各項(xiàng)工作,要經(jīng)常聯(lián)系、協(xié)作,共同抓好工程進(jìn)度,對(duì)交叉施工而影響工程進(jìn)度,要根據(jù)利益輕重來(lái)選擇,局部利益服從全局利益。
在現(xiàn)場(chǎng)安裝的各類(lèi)弱電進(jìn)口材料、設(shè)備,在安裝后要加強(qiáng)保護(hù)、制定可行的保護(hù)措施,在廣大職工中,講解對(duì)產(chǎn)品保護(hù)的重要性、嚴(yán)肅性,制定出相應(yīng)的保護(hù)、獎(jiǎng)懲制度。
智能化管理中心設(shè)備的安裝一定要在土建工程完成并裝修后進(jìn)行,達(dá)到無(wú)塵恒溫、防盜要求,開(kāi)始安裝機(jī)房設(shè)備、放線(xiàn)、對(duì)線(xiàn)、接線(xiàn),為系統(tǒng)的調(diào)試作好準(zhǔn)備。
在安裝設(shè)備時(shí),我們將充分研究說(shuō)明書(shū),方才進(jìn)行安裝,以避免安裝錯(cuò)誤。在進(jìn)行設(shè)備開(kāi)孔時(shí)。我們都將采用液壓開(kāi)孔器開(kāi)孔,以提高效率,并且美觀。
在安裝工程中,萬(wàn)用表、兆歐表是經(jīng)常使用的常用工具,我們將選用國(guó)家標(biāo)準(zhǔn)計(jì)量室校驗(yàn)過(guò)的CMC有效期內(nèi)對(duì)儀表進(jìn)行測(cè)量,使數(shù)據(jù)真實(shí)可靠。
我們?cè)诎惭b過(guò)程中將遵循以下原則:
l 安全
安全包括人生安全和設(shè)備運(yùn)行的安全,這就要求我們?cè)谑┕み^(guò)程中要注意安全,遵守各項(xiàng)安全操作規(guī)程,施工中對(duì)電纜電線(xiàn)的連接、接地及各項(xiàng)通電實(shí)驗(yàn)都應(yīng)一絲不茍,嚴(yán)格按照施工圖、施工規(guī)范和產(chǎn)品說(shuō)明書(shū)的規(guī)定進(jìn)行,確保產(chǎn)品的安全及運(yùn)行安全。
l 可靠
因弱電為弱電信號(hào),強(qiáng)調(diào)它的可靠性,不僅設(shè)計(jì)時(shí)要采取必要的措施,在施工中保證系統(tǒng)的可靠運(yùn)行更為重要,必須單獨(dú)接地,與強(qiáng)電接地分開(kāi)。
l 便利
因設(shè)計(jì)總是在圖紙上的,對(duì)運(yùn)行及維修未考慮周全,在安裝過(guò)程中,就應(yīng)充分考慮,使運(yùn)行和維修便利。
l 經(jīng)濟(jì)
在施工中,在能滿(mǎn)足設(shè)計(jì)要求的前提下,我們將大力加強(qiáng)對(duì)施工班組的管理,施工班組應(yīng)有專(zhuān)人對(duì)發(fā)給班組的各類(lèi)文件和圖紙進(jìn)行登記和妥善保管,不準(zhǔn)亂丟亂放。使用人不準(zhǔn)在圖紙上隨意涂改或勾畫(huà),要保護(hù)好文件和圖紙。班組要正確使用和保護(hù)好測(cè)試設(shè)備和儀器儀表,使用前應(yīng)先檢查技術(shù)狀況是否完好,是否有簽定標(biāo)志,要保證每道工序的正確性。班組要清楚知道所干的工作內(nèi)容、操作方法、檢驗(yàn)和記錄要求。
l 建筑工程的施工是比較復(fù)雜的,是各種專(zhuān)業(yè)空間交叉作業(yè)過(guò)程。弱電施工是整個(gè)建筑工程的一個(gè)組成部分,與其它各專(zhuān)業(yè)的施工必然發(fā)生多方面的交叉作業(yè),各施工專(zhuān)業(yè)間應(yīng)相互協(xié)調(diào)配合,以工程總體為目標(biāo),克服自身的困難。
l 在與其它安裝、土建交叉作業(yè)時(shí),必須做好成品的交接驗(yàn)收手續(xù)。
l 成品保護(hù)采取誰(shuí)施工誰(shuí)保護(hù),并加強(qiáng)班組成品保護(hù)意識(shí)。
l 對(duì)設(shè)備容易損壞的要加蓋保護(hù),作臨時(shí)封閉。
1、為加強(qiáng)現(xiàn)場(chǎng)管理,有計(jì)劃的組織施工建立必要的工程質(zhì)量、安全、速度保證體系,確保必要的工程按期保質(zhì)完成。
2、根據(jù)現(xiàn)場(chǎng)實(shí)際情況制定施工進(jìn)度計(jì)劃。
3、落實(shí)現(xiàn)場(chǎng)施工安全、防火措施。
4、項(xiàng)目部管理人員到位,施工隊(duì)勞動(dòng)力根據(jù)工程實(shí)際情況及時(shí)調(diào)配到位,保證施工進(jìn)度。
5、積極主動(dòng)搞好對(duì)監(jiān)理、甲方協(xié)調(diào)與配合。
6、設(shè)備安裝前及時(shí)報(bào)驗(yàn)與有關(guān)方面協(xié)商確定點(diǎn)位。
管路敷設(shè)時(shí),管路彎曲處不應(yīng)有褶皺、凹穴和裂縫現(xiàn)象。彎曲程度不應(yīng)大于管外徑的1/10,彎曲半徑不應(yīng)小于管外徑6倍。管入盒、箱、橋架處管口應(yīng)平整、無(wú)毛刺。管口露出箱盒應(yīng)小于5mm,用鎖母固定,接地處應(yīng)跨接良好。管口露出鎖母的絲扣2—4扣,并應(yīng)一管一孔,孔的大小應(yīng)與管徑相吻合,管道連接處清潔、美觀,電氣連接牢靠、嚴(yán)密。
1)管路超過(guò)下列長(zhǎng)度時(shí)應(yīng)加防水 防暴接線(xiàn)盒,無(wú)彎時(shí)30m,一個(gè)彎時(shí)20m,兩個(gè)彎時(shí)15m,三個(gè)彎時(shí)8m。如無(wú)法加接線(xiàn)盒時(shí),應(yīng)將管徑加大一號(hào)。
2)鐵制箱、盒嚴(yán)禁用電、氣焊開(kāi)孔,必須用專(zhuān)用開(kāi)孔器開(kāi)孔。
3)弱電系統(tǒng)的配線(xiàn)原則上可采用同槽分離方式敷設(shè),但電壓大于65V以上的輔助供電回路應(yīng)另管敷設(shè)。特別是視頻信號(hào)線(xiàn)與動(dòng)力線(xiàn)之間應(yīng)有良好屏蔽和隔離,防止信號(hào)竄擾和電磁干擾。
4)視頻線(xiàn)長(zhǎng)度不夠,需接頭時(shí),采用專(zhuān)用對(duì)接接頭連接,屏蔽線(xiàn)的屏蔽層與上位機(jī)及下位機(jī)要有可靠接地,接地電阻≤4Ω。
5)設(shè)備接線(xiàn)時(shí)接頭必須上焊錫再接入端子。開(kāi)關(guān)件安裝,其固定必須穩(wěn)固、牢靠,高度按規(guī)定標(biāo)準(zhǔn),并保證橫平、豎直。
6)精密設(shè)備安裝時(shí)帶手套操作。
7)線(xiàn)纜敷設(shè)時(shí),必須在電纜盤(pán)上方放出并保持松弛弧行。放線(xiàn)過(guò)程中線(xiàn)纜嚴(yán)禁打小圈,螺旋波浪等現(xiàn)象,視頻線(xiàn)中間如要接頭需專(zhuān)用電纜頭連接,多股線(xiàn)與設(shè)備使用銅線(xiàn)鼻進(jìn)行連接。
8)設(shè)備處導(dǎo)線(xiàn)連接時(shí)應(yīng)根據(jù)實(shí)際情況留有足夠的余量,導(dǎo)線(xiàn)兩端按圖紙?zhí)峁┑木€(xiàn)號(hào)標(biāo)簽進(jìn)行標(biāo)識(shí),根據(jù)編號(hào)進(jìn)行端子接線(xiàn)。
9)設(shè)備安裝牢固、美觀,頂裝設(shè)備橫豎成列,墻裝設(shè)備端正一致,資料整理正規(guī)、完整無(wú)遺漏,各種現(xiàn)場(chǎng)變更手續(xù)齊全有效。
工程設(shè)計(jì)圖 |
無(wú)法施工
現(xiàn)場(chǎng)調(diào)查 |
施工圖設(shè)計(jì)、理解 |
修改
備料、編制審訂施工方案 |
管線(xiàn)施工 |
返
工
不符合
停止 | 檢查 |
返
管線(xiàn)施工 |
工
不符合
停止 | 檢查 |
安裝調(diào)試 |
修
改
驗(yàn)收 |
交付使用 |
1、為加強(qiáng)智能化工程施工安裝質(zhì)量管理,規(guī)范智能化工程施工安裝單位質(zhì)量管理行為,提高智能化工程施工安裝質(zhì)量,根據(jù)有關(guān)建筑安裝法規(guī)、技術(shù)標(biāo)準(zhǔn),制定《南京競(jìng)豐達(dá)科技施工安裝質(zhì)量管理要點(diǎn)》。
2、智能化工程質(zhì)量管理應(yīng)貫徹“百年大計(jì)、質(zhì)量第一”方針,執(zhí)行有關(guān)建筑安裝法規(guī)和技術(shù)標(biāo)準(zhǔn)。
3、智能化工程質(zhì)量管理應(yīng)當(dāng)遵循相關(guān)質(zhì)量管理標(biāo)準(zhǔn),建立完善的質(zhì)量管理體系,編制規(guī)范化的體系文件,強(qiáng)化質(zhì)量控制、技術(shù)管理及工程保修等重點(diǎn)環(huán)節(jié)的管理,保證工程質(zhì)量。
1、 質(zhì)量管理機(jī)構(gòu)和職責(zé)
企業(yè)對(duì)工程質(zhì)量負(fù)全責(zé)。負(fù)責(zé)制定企業(yè)質(zhì)量方針、目標(biāo);對(duì)重大質(zhì)量工作進(jìn)行決策;組織編制、批準(zhǔn)發(fā)布質(zhì)量手冊(cè);建立健全企業(yè)質(zhì)量體系。
項(xiàng)目經(jīng)理部負(fù)責(zé)質(zhì)量體系文件在現(xiàn)場(chǎng)的具體實(shí)施和控制,實(shí)現(xiàn)質(zhì)量控制目標(biāo)。
2、 質(zhì)量檢驗(yàn)
工程實(shí)行三級(jí)質(zhì)量檢驗(yàn)制度:自檢驗(yàn)、專(zhuān)職檢驗(yàn),最終檢驗(yàn)。
施工班組在施工中,進(jìn)行自檢,質(zhì)檢員進(jìn)行專(zhuān)職復(fù)檢,項(xiàng)目經(jīng)理部(工程部)負(fù)責(zé)項(xiàng)目的最終預(yù)驗(yàn)。預(yù)驗(yàn)合格后,申報(bào)總包、監(jiān)理、甲方驗(yàn)收,并簽發(fā)驗(yàn)收單。
工程進(jìn)行檢驗(yàn)后都要如實(shí)記錄并報(bào)企業(yè)質(zhì)保部進(jìn)行復(fù)查,對(duì)不合格的,應(yīng)責(zé)令返工直至合格。
最終檢驗(yàn)合格后,出具書(shū)面申請(qǐng)竣工驗(yàn)收?qǐng)?bào)告,連同有關(guān)資料提交建設(shè)單位。憑驗(yàn)收合格的法律文書(shū)方可辦理移交使用手續(xù)。
3、質(zhì)量事故處理
制定質(zhì)量事故標(biāo)準(zhǔn),建立質(zhì)量事故處理機(jī)制。質(zhì)量事故一般分為一般事故和重大事故,一般事故可由項(xiàng)目經(jīng)理部負(fù)責(zé)處理,重大事故應(yīng)由企業(yè)組織處理。
4、質(zhì)量否決權(quán)
企業(yè)質(zhì)量管理部門(mén)、企業(yè)最高管理者代表(企業(yè)技術(shù)總負(fù)責(zé)人)、項(xiàng)目經(jīng)理、質(zhì)保工程師、項(xiàng)目技術(shù)負(fù)責(zé)人、專(zhuān)職質(zhì)檢員都應(yīng)按各自職責(zé),行使質(zhì)量否決權(quán),不允許不合格工序流到下一工序,更不允許檢驗(yàn)不合格工程交付驗(yàn)收。
施工過(guò)程中如發(fā)現(xiàn)設(shè)備、材料、設(shè)施、設(shè)計(jì)等問(wèn)題時(shí),施工人員和質(zhì)檢人員應(yīng)立即將有關(guān)情況向質(zhì)量體系實(shí)施負(fù)責(zé)人匯報(bào),并應(yīng)會(huì)同有關(guān)部門(mén)和人員分析問(wèn)題產(chǎn)生的原因,提出處理意見(jiàn),填寫(xiě)整改通知單和技術(shù)核定單。
項(xiàng)目經(jīng)理應(yīng)指定專(zhuān)人對(duì)質(zhì)量問(wèn)題認(rèn)真整改,質(zhì)檢員復(fù)查合格并簽字認(rèn)可后方可繼續(xù)施工。
1、施工質(zhì)量控制流程
施工質(zhì)量控制流程主要包括下列階段:
前期準(zhǔn)備、現(xiàn)場(chǎng)施工、隱蔽工程驗(yàn)收、檢驗(yàn)與試驗(yàn)、工程驗(yàn)收。
各系統(tǒng)施工質(zhì)量控制流程另行制定。
2、建立質(zhì)量分析制度
3、設(shè)備、材料質(zhì)量管理
建立設(shè)備材料采購(gòu)供應(yīng)制度,明確專(zhuān)人負(fù)責(zé)。對(duì)無(wú)生產(chǎn)許可證,無(wú)檢測(cè)報(bào)告,無(wú)使用說(shuō)明書(shū),無(wú)合格證無(wú)商標(biāo)的設(shè)備材料嚴(yán)禁采購(gòu)或使用。設(shè)備材料進(jìn)場(chǎng)時(shí)應(yīng)當(dāng)場(chǎng)進(jìn)行檢查,并如實(shí)填寫(xiě)檢查記錄,不符合有關(guān)要求的不得進(jìn)場(chǎng)安裝。嚴(yán)格執(zhí)行進(jìn)場(chǎng)報(bào)驗(yàn)制度設(shè)備材料如不符合產(chǎn)品質(zhì)量要求,項(xiàng)目部拒絕接受和安裝。
4、質(zhì)量管理資料
按統(tǒng)一質(zhì)量記錄如實(shí)填寫(xiě)。
質(zhì)量管理資料不全的工程,不得交付驗(yàn)收。
施工安裝質(zhì)量按規(guī)范記錄。
5、 檔案管理
建立工程竣工資料檔案。
1、實(shí)行質(zhì)量保修。工程竣工驗(yàn)收時(shí)必須同時(shí)提交質(zhì)量保修書(shū),質(zhì)量保修書(shū)中應(yīng)明確保修范圍、保修期限和保修責(zé)任。
2、針對(duì)“****”智能化項(xiàng)目免費(fèi)保修期限一般為二年半。保修期自竣工驗(yàn)收合格之日起計(jì)算。
3、在保修期和保修范圍內(nèi)發(fā)生質(zhì)量問(wèn)題時(shí),施工單位應(yīng)當(dāng)履行保修義務(wù)。
4、保修期滿(mǎn)后,可按有關(guān)規(guī)定簽訂智能化設(shè)施維護(hù)保修協(xié)議(合同)。
5、實(shí)行質(zhì)量回訪制度.工程交付后,應(yīng)逐個(gè)建立工程保修檔案,保修期內(nèi)應(yīng)定期組織回訪,并如實(shí)填寫(xiě)工程質(zhì)量回訪記錄表。
1、土建工程全部結(jié)束,現(xiàn)場(chǎng)清掃整理完畢。
2、電氣設(shè)備絕緣電阻符合要求,各種繼電保護(hù)及儀表指示鑒定試驗(yàn)已經(jīng)做完。
3、控制回路、保護(hù)、測(cè)量等回路調(diào)試完畢,動(dòng)作正常。
4、接線(xiàn)箱外殼油漆完整,保護(hù)接地良好。
5、接線(xiàn)箱門(mén)活動(dòng)部分轉(zhuǎn)動(dòng)靈活,無(wú)碰卡現(xiàn)象。
6、接線(xiàn)線(xiàn)路的連接證實(shí)為正確,包括電源相位、極性等均正確。
7、所發(fā)生的問(wèn)題均應(yīng)記錄準(zhǔn)確,并將質(zhì)量問(wèn)題或故障排除記錄于表內(nèi)。
本系統(tǒng)對(duì)于用戶(hù)能否按期使用并盡快達(dá)到理想狀態(tài)是至關(guān)重要的,經(jīng)驗(yàn)告訴我們,如果僅僅在安裝全部完成后進(jìn)行調(diào)試,往往會(huì)將工程的驗(yàn)收一拖再拖,因此我們調(diào)試工作和安裝是交叉進(jìn)行的,安裝一套設(shè)備調(diào)試一套設(shè)備,當(dāng)各系統(tǒng)的安裝基本結(jié)束,調(diào)試工作也已完成了一半。
在開(kāi)始調(diào)試工作前,首先檢查調(diào)試使用的儀器是否經(jīng)過(guò)有關(guān)部門(mén)的檢驗(yàn)是否達(dá)到國(guó)家有關(guān)的計(jì)量標(biāo)準(zhǔn),只有合格的儀器才能在調(diào)試中使用。
調(diào)試時(shí)先用儀器檢查接線(xiàn)是否正確,是否有短路或斷路,在確認(rèn)無(wú)誤的情況下,開(kāi)始系統(tǒng)內(nèi)各子系統(tǒng)通電調(diào)試。在解決所有問(wèn)題后,各個(gè)子系統(tǒng)聯(lián)機(jī)調(diào)試,直至調(diào)試完成。然后各相關(guān)聯(lián)網(wǎng)的子系統(tǒng)進(jìn)行集成調(diào)試,調(diào)試的各個(gè)階段做好調(diào)試記錄,并打印簽名,裝訂作為工程驗(yàn)收資料,在達(dá)到系統(tǒng)功能后交付業(yè)主為止。
1、項(xiàng)目按合同規(guī)定全部建成后,憑運(yùn)行達(dá)到設(shè)計(jì)要求,并經(jīng)我公司指揮部、項(xiàng)目部、施工隊(duì)進(jìn)行初驗(yàn),寫(xiě)出運(yùn)行報(bào)告。提請(qǐng)監(jiān)理、業(yè)主進(jìn)行驗(yàn)收。
2、工程驗(yàn)收小組組成:
業(yè)主、監(jiān)理、施工單位及有關(guān)單位組成。按合同和有關(guān)規(guī)范規(guī)定進(jìn)行
驗(yàn)收,驗(yàn)收時(shí)做好記錄,簽署驗(yàn)收證書(shū),并立卷歸檔。
3、為保證工程質(zhì)量,確保系統(tǒng)正常和工程順利移交,驗(yàn)收分材料設(shè)備驗(yàn)收、施工驗(yàn)收及系統(tǒng)運(yùn)行驗(yàn)收三部分進(jìn)行。
產(chǎn)品質(zhì)量驗(yàn)收:向業(yè)主、監(jiān)理提供產(chǎn)品質(zhì)量證明,由監(jiān)理、業(yè)主簽證驗(yàn)收。
系統(tǒng)運(yùn)行驗(yàn)收:當(dāng)系統(tǒng)設(shè)備單體調(diào)試運(yùn)行無(wú)誤后,進(jìn)行系統(tǒng)聯(lián)調(diào),調(diào)試完畢后向業(yè)主提交系統(tǒng)調(diào)試報(bào)告并書(shū)面通知監(jiān)理、業(yè)主進(jìn)行系統(tǒng)運(yùn)行驗(yàn)收。業(yè)主可會(huì)同有關(guān)部門(mén)或組織專(zhuān)家按合同所規(guī)定的設(shè)計(jì)及技術(shù)要求進(jìn)行系統(tǒng)驗(yàn)收并辦理驗(yàn)收手續(xù)。
施工驗(yàn)收:應(yīng)符合現(xiàn)行國(guó)家標(biāo)準(zhǔn)《電氣裝置工程施工及驗(yàn)收規(guī)范》以及《全國(guó)住宅小區(qū)智能化系統(tǒng)示范工程建設(shè)要點(diǎn)與技術(shù)導(dǎo)則(試行)》的規(guī)定,并應(yīng)符合設(shè)計(jì)要求,施工驗(yàn)收包括設(shè)備安裝和管線(xiàn)敷設(shè)兩部分。
本項(xiàng)目的安全目標(biāo)是“零事故”
1、項(xiàng)目經(jīng)理
項(xiàng)目經(jīng)理是健康安全環(huán)保工作的第一責(zé)任人,對(duì)健康安全環(huán)保 工作負(fù)全面的責(zé)任。
1、 健康安全經(jīng)理
協(xié)助項(xiàng)目經(jīng)理管理和執(zhí)行健康安全環(huán)保計(jì)劃,為健康安全環(huán)保工作的具體負(fù)責(zé)人。
2、 綜合辦公室
綜合辦公室負(fù)責(zé)生活后勤的健康安全工作。
總的原則是執(zhí)行“****”的安全管理規(guī)章制度和我公司安全管理制度及政府的有關(guān)法規(guī)并接受監(jiān)督。
1、安全教育
對(duì)所有進(jìn)入工地施工人員進(jìn)行一次安全教育,進(jìn)場(chǎng)戴好安全帽,扣好帽帶,用好安全三件寶。安全教育的目的是提高職工的安全意識(shí)和自我保護(hù)的能力,熟知本系統(tǒng)、本工種、本崗位的安全技術(shù)規(guī)程,避免各類(lèi)事故的發(fā)生,本安全教育的形式為進(jìn)場(chǎng)教育。
2、安全檢查
1)安全檢查是做好健康安裝工作的重要手段之一,能及時(shí)發(fā)現(xiàn)事故隱患,及時(shí)制止“三違”(違章作業(yè)、違章指揮、違反勞動(dòng)紀(jì)律)的行為發(fā)生,保證各項(xiàng)安全管理規(guī)章制度落到實(shí)處,從而杜絕事故的發(fā)生。
2)安全檢查實(shí)行領(lǐng)導(dǎo)檢查和基層自查相結(jié)合,全面檢查和專(zhuān)業(yè)檢查相結(jié)合的原則。
3)安全檢查的內(nèi)容是:查領(lǐng)導(dǎo)、查制度、查機(jī)械設(shè)備、查安全設(shè)施、查教育培訓(xùn)、查操作行為、查勞保用品使用、查事故處理等。
4)季節(jié)性安全檢查。春季應(yīng)以防雪、解凍、跑漏、防臨時(shí)建筑物倒塌為重點(diǎn),夏季應(yīng)以防暑降溫、防觸電、防臺(tái)風(fēng)、防汛為重點(diǎn),秋冬季以防火防爆、防滑為重點(diǎn)。
5)所有檢查均必須按安全檢查進(jìn)行,并做好記錄。
6)基層檢查均必須按安全檢查進(jìn)行,并做好記錄。
7)領(lǐng)導(dǎo)檢查中發(fā)現(xiàn)的隱患應(yīng)下達(dá)書(shū)面的《事故隱患整改通知單》,限期整改。
8)所有的事故隱患必須書(shū)面報(bào)告給業(yè)主,報(bào)告內(nèi)容包括事故性質(zhì),發(fā)生時(shí)間、地點(diǎn)、原因等。
3、隱患整改
1)接《事故隱患整改通知單》后,責(zé)任人應(yīng)立即組織整改,做到“三定”(定具體整改人員、定整改措施、定整改完成時(shí)間);
2)隱患整改完畢及時(shí)將整改結(jié)果書(shū)面反饋給該通知發(fā)出人,并書(shū)面報(bào)告業(yè)主;
3)通知發(fā)出人收到反饋情況后,要復(fù)驗(yàn)整改結(jié)果。
4、應(yīng)急計(jì)劃
目的是正確、及時(shí)處理意外情況,防止事故擴(kuò)大,將事故損失控制在最小范圍內(nèi)。
1)現(xiàn)場(chǎng)每個(gè)人都應(yīng)熟悉各種意外事件應(yīng)急程序,熟悉各種意外事件急救方法,熟悉各種應(yīng)急器材的使用方法。
2)現(xiàn)場(chǎng)急救,對(duì)控制事故損失,防止事故擴(kuò)大十分重要。例如發(fā)生火災(zāi),應(yīng)注意初起火災(zāi)的及時(shí)撲救。發(fā)生觸電事故,應(yīng)立即切斷電源,注重在現(xiàn)場(chǎng)就地進(jìn)行心肺復(fù)蘇術(shù)。
3)在現(xiàn)場(chǎng)急救的同時(shí)報(bào)告上級(jí),尋求外援。尋找外援時(shí)不要驚慌,如尋求火警救援時(shí),應(yīng)說(shuō)明著火地點(diǎn),著火物質(zhì),并派人在主要路口接應(yīng),引導(dǎo)消防車(chē)
4)保護(hù)現(xiàn)場(chǎng)。
5、事故管理
1)發(fā)生事故后,立即報(bào)告項(xiàng)目經(jīng)理。
2)根據(jù)事故情況,組成不同等級(jí)的調(diào)查組。按“四不放過(guò)”(事故原因不查清不放過(guò),沒(méi)有防范措施不放過(guò),責(zé)任人及廣大群眾沒(méi)有受到教育不放過(guò),有關(guān)責(zé)任人不查處不放過(guò))的原則辦理。
3)對(duì)傷亡事故隱瞞不報(bào)者要追究責(zé)任,從嚴(yán)處理。
4)重大事故,根據(jù)我國(guó)規(guī)定應(yīng)報(bào)告有關(guān)政府部門(mén)。
5)及時(shí)將事故情況書(shū)面報(bào)告承包商(內(nèi)容包括事故性質(zhì)、發(fā)生時(shí)間、地點(diǎn)、原因等)。
6、文明施工措施
1)進(jìn)入施工現(xiàn)場(chǎng)的,每一名職工必須著統(tǒng)一的公司工作服、安全帽,佩戴表明身份的胸卡。
2)施工作業(yè)時(shí)嚴(yán)禁打鬧、搞笑,嚴(yán)禁亂扔工具和雜物,施工人員不得擅自離開(kāi)工作崗位。如須帶電作業(yè)時(shí),應(yīng)穿絕緣鞋,并有專(zhuān)人監(jiān)護(hù)。
3)使用手持電動(dòng)工具,在線(xiàn)路首端必須接漏電保護(hù)器,使用前對(duì)電動(dòng)工具進(jìn)行安全測(cè)試。
4)特殊工種人員須持證上崗(如電工、電焊工)。嚴(yán)禁盜竊和損壞公共及他人財(cái)物,一經(jīng)發(fā)現(xiàn)將嚴(yán)肅查處。上班時(shí)嚴(yán)禁飲酒、鬧事、防止意外事故發(fā)生。注意環(huán)境衛(wèi)生,保持施工和生活場(chǎng)所的清潔,嚴(yán)禁隨地大小便,施工中做到隨清,工完料清。
5)施工車(chē)輛、人員、物資的進(jìn)場(chǎng)路線(xiàn)嚴(yán)格按業(yè)主的要求出入。
6)占用道路時(shí)應(yīng)提前向甲方提出申請(qǐng),允許后按時(shí)完成作業(yè),以免引起交通堵塞,每日作業(yè)完畢,應(yīng)將電焊線(xiàn),零星材料、機(jī)具等收好放在指定位置,做到“日清”。
7)施工區(qū)域內(nèi),每日施工結(jié)束后,應(yīng)自動(dòng)清理現(xiàn)場(chǎng)。
8)每周五下午,由項(xiàng)目經(jīng)理帶領(lǐng)全體施工人員進(jìn)行場(chǎng)地大清理,大整頓。
搞好本項(xiàng)目施工中的物資計(jì)劃、采購(gòu)、領(lǐng)用、供應(yīng)工作、適時(shí)、適地、按質(zhì)、按量地組織好工作物資供應(yīng),確保工程的順利進(jìn)行。
建立供應(yīng)臺(tái)帳輸入微機(jī) |
|
編制供應(yīng)材料的領(lǐng)用計(jì)劃 |
編制自行采購(gòu)材料的采購(gòu)計(jì)劃 |
合同訂貨、市場(chǎng)采購(gòu) |
貨物提運(yùn) |
驗(yàn)收入庫(kù) |
|
進(jìn)入倉(cāng)庫(kù)管理工作流程 |
l 根據(jù)計(jì)劃部門(mén)提供的月、旬、周計(jì)劃,確定物資的需用量編制物資需要計(jì)劃;建立工程物資供應(yīng)臺(tái)帳,輸入計(jì)算機(jī),利用微機(jī)進(jìn)行動(dòng)態(tài)管理。
l 根據(jù)需要計(jì)劃,確定物資的領(lǐng)用量、采購(gòu)量。
l 按供應(yīng)范圍編制物資的領(lǐng)用計(jì)劃、采購(gòu)計(jì)劃。
l 物資采購(gòu)計(jì)劃報(bào)主管審批交采購(gòu)員實(shí)施。
l 對(duì)供貨方的質(zhì)量保證能力的評(píng)價(jià)。
l 對(duì)產(chǎn)品試驗(yàn)結(jié)果進(jìn)行評(píng)價(jià)。
l 對(duì)供貨方的供貨、業(yè)績(jī)和信譽(yù)進(jìn)行評(píng)價(jià)。
l 對(duì)評(píng)定結(jié)果作好記錄。
l 對(duì)評(píng)定合格的供貨方應(yīng)列出名單,建立檔案。
l 在合格供貨方名單內(nèi)采購(gòu)。
l 對(duì)入庫(kù)物資進(jìn)行數(shù)量、質(zhì)量進(jìn)行驗(yàn)收。
l 物資到達(dá)前應(yīng)通知倉(cāng)庫(kù)保管員根據(jù)將到物資做好準(zhǔn)備。
l 物資到達(dá)時(shí),倉(cāng)庫(kù)保管員根據(jù)入庫(kù)憑證對(duì)進(jìn)庫(kù)物資的名稱(chēng)、規(guī)格、型號(hào)、等級(jí)、數(shù)量進(jìn)行核對(duì)、清點(diǎn)。
l 對(duì)隨貨的質(zhì)量證明資料進(jìn)行清點(diǎn),并做好交接記錄。
l 清點(diǎn)無(wú)誤的物資應(yīng)填寫(xiě)物資送檢通知單,由材料、設(shè)備質(zhì)檢員對(duì)進(jìn)貨物資進(jìn)行驗(yàn)收。
l 管材、板材必須貼有材料名稱(chēng)、規(guī)格、等級(jí)、爐號(hào)。
l 材料質(zhì)檢員應(yīng)根據(jù)合同文件、工程需要確定是否進(jìn)行驗(yàn)收和試驗(yàn)。
l 當(dāng)合同中規(guī)定甲方對(duì)承包方提供的物資進(jìn)行驗(yàn)收時(shí),有權(quán)在本單位或承包方處對(duì)物資是否符合規(guī)定要求進(jìn)行驗(yàn)證。
l 驗(yàn)證或檢驗(yàn)不合格的材料要隔離存放,并有標(biāo)識(shí)。
l 未經(jīng)驗(yàn)收或檢驗(yàn)不合格的物資一律禁止用于工程。
●當(dāng)材料與合同工作范圍,項(xiàng)目說(shuō)明書(shū)、采購(gòu)合同、施工圖紙不一致,應(yīng)出材料缺陷報(bào)告,并應(yīng)退給供貨商,當(dāng)不可能退回時(shí)(如計(jì)劃要求)缺陷材料應(yīng)根據(jù)甲方的要求進(jìn)行修理,只有甲方才有權(quán)通知接收與合同文件不一致的材料。
l 對(duì)檢驗(yàn)合格的物資應(yīng)及時(shí)辦理手續(xù),并按合同要求承付貨款。
1、材料發(fā)放必須保持以下原則。
l 發(fā)放數(shù)量必須限制在批準(zhǔn)數(shù)量?jī)?nèi),不得任意多發(fā)。
l 如因包裝所限或不便拆零需超發(fā)時(shí),應(yīng)報(bào)專(zhuān)業(yè)計(jì)劃同意。
l 未經(jīng)驗(yàn)證或檢驗(yàn)不合格的材料不準(zhǔn)出庫(kù)。
l 技術(shù)資料(如合格證、質(zhì)保書(shū)、說(shuō)明書(shū)、圖紙等)應(yīng)辦理交接登記后隨貨同行,零發(fā)時(shí),要有抄件或復(fù)件,原件留存。
2、發(fā)料單據(jù)及時(shí)輸入計(jì)算機(jī)進(jìn)行帳務(wù)處理;做到計(jì)帳及時(shí)日清月結(jié)。
3、收發(fā)手續(xù)齊備、憑證完整、裝訂成冊(cè)。
1、保管
1)要方便材料的收、發(fā)、盤(pán)點(diǎn)和做清潔衛(wèi)生工作。
2)要符合安全技術(shù)管理和規(guī)格化要求。
3)按物資性能分類(lèi)管理。
4)入庫(kù)物資若無(wú)質(zhì)量證明書(shū)不能進(jìn)行質(zhì)量驗(yàn)收,可先進(jìn)行數(shù)量驗(yàn)收,等質(zhì)量證明書(shū)到達(dá)后再補(bǔ)驗(yàn)質(zhì)量。
5)易碎、易損及精密度較高的儀器、儀表、電氣材料、存于專(zhuān)設(shè)的電儀庫(kù)內(nèi),按標(biāo)識(shí)存放,輕拿輕放,不得倒置、碰撞、滾動(dòng)和擠壓。
6)成套設(shè)備必須配套存放,主機(jī)、附件、專(zhuān)用工具不得分散存放,嚴(yán)禁拆套使用。
2、維護(hù)保養(yǎng)
1)保管中應(yīng)加強(qiáng)維護(hù)保養(yǎng),達(dá)到“十不”即:不銹、不潮、不凍、不腐、不變、不壞、不漏、不混、不爆。做到發(fā)放無(wú)差錯(cuò),保管無(wú)丟失。
2)電氣、儀表設(shè)備進(jìn)庫(kù)存放,露天存放的應(yīng)下墊上蓋,注意防濕、防曬。
對(duì)發(fā)生收、發(fā)的材料當(dāng)日進(jìn)行盤(pán)點(diǎn),以便及時(shí)發(fā)現(xiàn)問(wèn)題。沒(méi)有發(fā)生收發(fā)的材料,用抽查的辦法進(jìn)行核對(duì)。做到帳、卡、物、資金四對(duì)口。
第十二章、施工機(jī)具計(jì)劃
主要施工機(jī)具一覽表
序號(hào) | 設(shè)備名稱(chēng) | 型號(hào) | 單位 | 數(shù)量 | 新舊程度 | 備注 |
1 | 電焊機(jī) | 380V/220V | 臺(tái) | 2 | 2003年 | 國(guó)產(chǎn) |
2 | 沖擊電錘 | 220V | 臺(tái) | 5 | 2000/2003年 | 日立 |
3 | 手槍電鉆 | 220V | 臺(tái) | 4 | 2003年 | 日立 |
4 | 切割機(jī) | 380V/220V | 臺(tái) | 1 | 2002年 | 國(guó)產(chǎn) |
5 | 切割機(jī) | 320V/220V | 臺(tái) | 1 | 2003年 | 進(jìn)口 |
6 | 接地?fù)u表 | 臺(tái) | 1 | 2003年 | 國(guó)產(chǎn) | |
7 | 彎管器 | φ16~φ60 | 臺(tái) | 2 | 2002年 | 國(guó)產(chǎn) |
8 | 搖表 | 500V | 臺(tái) | 2 | 2004年 | 國(guó)產(chǎn) |
9 | 萬(wàn)用表 | DT-830B | 只 | 1 | 2004年 | 國(guó)產(chǎn) |
10 | 頻譜儀 | HP-8563 | 臺(tái) | 1 | 2002年 | 進(jìn)口 |
11 | 網(wǎng)絡(luò)測(cè)試儀 | TDS-220 | 臺(tái) | 1 | 2003年 | 進(jìn)口 |
12 | 示波器 | HITACHI1560 | 臺(tái) | 1 | 2000年 | 進(jìn)口 |
13 | 穩(wěn)壓電源 | DH-1718 | 臺(tái) | 4 | 2000年 | 國(guó)產(chǎn) |
14 | 對(duì)講機(jī) | M | 臺(tái) | 4 | 2003年 | 進(jìn)口 |
15 | 工程打印機(jī) | LS3E | 臺(tái) | 1 | 2003年 | 進(jìn)口 |
16 | 工具 | 批 | ||||
17 | 工程車(chē) | 輛 |
從智能化管理中心到各設(shè)備點(diǎn)做一環(huán)狀網(wǎng)路,分支處設(shè)若干豎井,豎井要考慮排水及穿線(xiàn)。環(huán)狀網(wǎng)路總線(xiàn)敷設(shè)應(yīng)順著通訊電纜走線(xiàn)。
1、無(wú)償提供本工程建筑平面藍(lán)圖、結(jié)構(gòu)藍(lán)圖各一套;
2、請(qǐng)甲方協(xié)調(diào)弱電、強(qiáng)電、給排水、消防、土建、煤氣等單位可能出現(xiàn)的交叉施工;
3、請(qǐng)甲方落實(shí)各單位項(xiàng)目負(fù)責(zé)人及其聯(lián)系電話(huà);
4、請(qǐng)甲方定期召開(kāi)工程例會(huì),以解決施工中出現(xiàn)的問(wèn)題;
5、請(qǐng)甲方提供施工用電、生活用電、生活用水的條件;
6、請(qǐng)甲方提供工地住宿的條件;
7、請(qǐng)甲方提供材料堆放保管的場(chǎng)所,并提供保安服務(wù);
8、請(qǐng)甲方提供上下樓層垂直運(yùn)輸?shù)谋憷?/span>
安防報(bào)警系統(tǒng)是智能小區(qū)實(shí)現(xiàn)安全管理的重要系統(tǒng)。我們對(duì)小區(qū)設(shè)計(jì)住戶(hù)報(bào)警系統(tǒng)的主要目的是確保住宅、住戶(hù)安全,生活中人人都可能出現(xiàn)一些意想不到的求助情況,現(xiàn)代居住的格局鄰里不相往來(lái)已是常事,家庭生活隱秘性、封閉性越來(lái)越強(qiáng)。因而要求每個(gè)住戶(hù)的家居防范報(bào)警系統(tǒng)在實(shí)際可能發(fā)生受侵害或病人需要緊急幫助的情況下,通過(guò)報(bào)警系統(tǒng)能夠向小區(qū)安防中心呼救報(bào)警,中心能夠根據(jù)報(bào)警信息迅速處理。因此,有必要為小區(qū)住戶(hù)的安全提供保障系統(tǒng)。
家庭報(bào)警的防護(hù)區(qū)域分成兩部分,即住宅周界防護(hù)和住宅內(nèi)區(qū)域防護(hù)。住宅周界是指住宅門(mén)、窗上安裝報(bào)警裝置,住宅內(nèi)區(qū)域防護(hù)是指在主要通道、重要房間內(nèi)安裝報(bào)警裝置。
1、接收住戶(hù)室內(nèi)紅外幕簾探測(cè)器、緊急按鈕的實(shí)時(shí)報(bào)警信息,并可顯示地址碼和警情類(lèi)型以及報(bào)警時(shí)間。
2、錄入、修改、打印用戶(hù)的信息,統(tǒng)計(jì)查詢(xún)用戶(hù)信息,建立用戶(hù)檔案;
3、實(shí)時(shí)維護(hù)用戶(hù)的撤布防信息、測(cè)試信息;
4、按接警、處警方法、警情性質(zhì)查找統(tǒng)計(jì)各種警情信息,統(tǒng)計(jì)顯示各種報(bào)警及誤報(bào)原因,自動(dòng)計(jì)算誤報(bào)率以便輔助中心管理,降低誤報(bào)。
5、可以根據(jù)住戶(hù)需求擴(kuò)展、調(diào)整探測(cè)器數(shù)量和位置;
6、可以生成報(bào)告、日志并給予保存。
從每個(gè)探測(cè)器暗敷一根PVC20管至家居報(bào)警控制通訊主機(jī)安裝部位,再由家居報(bào)警控制通訊主機(jī)(數(shù)碼家庭終端)安裝部位暗敷一根PVC20管至每戶(hù)寬帶接入點(diǎn),管子型號(hào)、規(guī)格、走向參照弱電管網(wǎng)綜合施工平面圖。
家居報(bào)警主要有紅外幕簾探測(cè)器、緊急按鈕、報(bào)警鍵盤(pán)、報(bào)警中心組成。我們?cè)诎惭b前應(yīng)注意以下幾點(diǎn):
1、紅外幕簾探測(cè)器、緊急按鈕管線(xiàn)是否到位;
2、對(duì)紅外幕簾探測(cè)器、緊急按鈕逐一進(jìn)行檢查、測(cè)試,各項(xiàng)技術(shù)指標(biāo)是否符合要求;
3、對(duì)線(xiàn)纜進(jìn)行通斷及對(duì)地測(cè)試;
4、線(xiàn)纜標(biāo)記是否清晰、齊全;
5、住戶(hù)內(nèi)墻壁是否涂刷;
6、按施工圖紙的要求進(jìn)行安裝。
探測(cè)器安裝于窗框上方內(nèi)側(cè)或窗框上方梁內(nèi)側(cè),在住戶(hù)離開(kāi)房屋對(duì)設(shè)防區(qū)域進(jìn)行設(shè)防的狀態(tài)下,如果有人走近紅外射線(xiàn)防范范圍,則探測(cè)器立刻向現(xiàn)場(chǎng)報(bào)警接收裝置發(fā)送觸發(fā)信號(hào),同時(shí),報(bào)警模塊向中心報(bào)警,中心接收?qǐng)?bào)警信號(hào),顯示報(bào)警信息。該探測(cè)器接入家居報(bào)警控制通訊主機(jī),即可以對(duì)其進(jìn)行設(shè)防和撤防。在每一住戶(hù)主臥室設(shè)置兩個(gè)緊急按鈕。在任何時(shí)候只要住戶(hù)受到暴力威脅、挾持、突發(fā)疾病等需要向外界緊急求助的時(shí)候均可觸發(fā)緊急按鈕,緊急按鈕立刻向現(xiàn)場(chǎng)報(bào)警接收裝置即可視對(duì)講的報(bào)警模塊發(fā)送觸發(fā)信號(hào),同時(shí),報(bào)警模塊向中心報(bào)警,中心接收?qǐng)?bào)警信號(hào),電腦顯示器上顯示報(bào)警信息。緊急按鈕接入家居報(bào)警控制通訊主機(jī)24小時(shí)防區(qū),即無(wú)論此時(shí)處于設(shè)防或撤防狀態(tài),觸發(fā)它均可向中心報(bào)警。
閉路電視監(jiān)控系統(tǒng)通過(guò)在小區(qū)主要通道、休閑區(qū)和出入口、地下車(chē)
庫(kù)等公共活動(dòng)區(qū)域及小區(qū)周界重要區(qū)段、電梯轎廂等處設(shè)置前端攝像設(shè)備,實(shí)時(shí)、直觀、真實(shí)地將被監(jiān)視對(duì)象的圖像傳送到組團(tuán)管理中心,中心對(duì)本組團(tuán)內(nèi)的區(qū)域進(jìn)行實(shí)時(shí)監(jiān)控和記錄,使值班管理人員充分了解小區(qū)的動(dòng)態(tài),提供有效的安全防范手段。
攝像機(jī)部分
攝象機(jī)到硬盤(pán)錄像機(jī)采用同軸電纜傳輸所有的視頻信號(hào)。
控制信號(hào)采用屏蔽電纜傳輸,其優(yōu)點(diǎn)為:技術(shù)先進(jìn),可以減輕設(shè)備復(fù)雜化,相互無(wú)雜波干擾,性能穩(wěn)定可靠,維護(hù)方便。
電源采用交流220V或DC12V供電,根據(jù)功能要求供電。
控制信號(hào)、視頻信號(hào)和電源電纜分管敷設(shè),防止互相干擾。
1)數(shù)字硬盤(pán)錄像機(jī)等中心機(jī)房設(shè)備由機(jī)房統(tǒng)一供電。
2)前端攝像機(jī)等電源供應(yīng)采用機(jī)房UPS集中供給,與信號(hào)線(xiàn)分管敷設(shè)。
每只攝像機(jī)需敷設(shè)1根SYV75-5視頻線(xiàn)和1根RVV2*1.0電源線(xiàn);攝像機(jī)視頻線(xiàn)、電源線(xiàn)、車(chē)庫(kù)內(nèi)直接進(jìn)橋架或通過(guò)DN25的管子就近接入水平橋架,弱電間沿垂直橋架經(jīng)外管網(wǎng)至智能化管理中心,管子型號(hào)、規(guī)格及走向參照弱電管網(wǎng)綜合施工平面圖。
我們?cè)诎惭b前攝像機(jī)應(yīng)注意以下幾點(diǎn):
1、攝像機(jī)管線(xiàn)是否到位;
2、對(duì)每只攝像機(jī)逐一進(jìn)行檢查、測(cè)試,各項(xiàng)技術(shù)指標(biāo)是否符合要求;
3、對(duì)攝像機(jī)電纜進(jìn)行通斷及對(duì)地測(cè)試;
4、線(xiàn)纜標(biāo)記是否清晰、齊全;
5、按施工圖紙的要求進(jìn)行施工。
可視對(duì)講系統(tǒng)主要實(shí)現(xiàn)來(lái)訪者的身份鑒別和控制。系統(tǒng)主要通過(guò)在小區(qū)各主要出入口安裝一套帶攝像機(jī)的可視對(duì)講門(mén)口機(jī),住戶(hù)內(nèi)安裝一臺(tái)可視對(duì)講分機(jī),攝像機(jī)所攝到的圖像通過(guò)網(wǎng)絡(luò)傳輸?shù)阶?hù)家中,這樣住戶(hù)可以在屏幕上看到來(lái)訪者的圖像從而了解來(lái)訪者的身份。以確定開(kāi)門(mén)放行。通過(guò)可視分機(jī),住戶(hù)可以直接呼叫門(mén)口機(jī)和管理中心,管理中心顯示房間號(hào)碼,可以進(jìn)行可視對(duì)講。管理中心也可以呼叫住戶(hù)進(jìn)行可視對(duì)講。
1、訪客通過(guò)按動(dòng)每個(gè)樓棟門(mén)口機(jī)的住戶(hù)房間代碼呼叫住戶(hù),住戶(hù)通過(guò)屏幕判斷訪客的合法性,如合法則按動(dòng)開(kāi)門(mén)按鈕放行,否則不予開(kāi)門(mén)。
2、晚間呼叫不影響視覺(jué)效果。
3、住戶(hù)和中心實(shí)現(xiàn)雙向呼叫。
從每戶(hù)室內(nèi)可視對(duì)講分機(jī)安裝部位暗敷一根PVC25管至弱電井的垂直橋架,進(jìn)入控制箱體,分支管到單元門(mén)、通過(guò)外管網(wǎng)到中心機(jī)房,接入到圍墻機(jī)上。這樣就可以實(shí)現(xiàn)樓宇對(duì)講系統(tǒng)的聯(lián)網(wǎng)。
我們?cè)诎惭b可視對(duì)講系統(tǒng)時(shí),必須注意以下幾點(diǎn):
? 管線(xiàn)是否到位;
? 對(duì)系統(tǒng)各設(shè)備逐一進(jìn)行檢查、測(cè)試。各項(xiàng)技術(shù)指標(biāo)是否符合技術(shù)要求;
? 對(duì)線(xiàn)纜進(jìn)行通斷及對(duì)地測(cè)試;
? 線(xiàn)纜標(biāo)記清晰、齊全;
? 住戶(hù)內(nèi)墻壁是否粉刷;
? 按施工圖紙的要求進(jìn)行安裝。
為了建立封閉式的小區(qū),加強(qiáng)出入口管理,防范小區(qū)外閑雜人員進(jìn)入,同時(shí)防范非法翻越圍墻或柵欄。
本系統(tǒng)建立了周界防范報(bào)警系統(tǒng),具體設(shè)計(jì)如下:
在小區(qū)周邊安裝紅外對(duì)射探測(cè)器。當(dāng)發(fā)生非法翻越時(shí),現(xiàn)場(chǎng)報(bào)警器可立即將警情傳送到智能化管理中心,中心電腦將在電子地圖上顯示出翻越區(qū)域、時(shí)間、編號(hào)等,以利于保安人員及時(shí)準(zhǔn)確地處理。
(1)周界全面設(shè)防,無(wú)盲區(qū)和死角
(2)探測(cè)器抗不良天氣環(huán)境干擾能力強(qiáng);
(3)報(bào)警中心具備警笛提示;中心通過(guò)電子地圖識(shí)別報(bào)警區(qū)域;
(4)翻越區(qū)域現(xiàn)場(chǎng)報(bào)警,現(xiàn)場(chǎng)同時(shí)發(fā)出警號(hào)警告;
(5)報(bào)警中心可控制前端設(shè)備狀態(tài)的恢復(fù);
(6)報(bào)警中心具有報(bào)警狀態(tài)、報(bào)警時(shí)間記錄功能。
周界防越系統(tǒng)主要由紅外對(duì)射報(bào)警器、地址碼模塊、報(bào)警主機(jī)等組成。
紅外探測(cè)器需從智能化管理中心敷設(shè)一根RVV4*1.0線(xiàn)至現(xiàn)場(chǎng),采用總線(xiàn)制連接,紅外探測(cè)器線(xiàn)用PE32管暗敷至室外就近電信井,然后沿此電信井暗敷至現(xiàn)場(chǎng),管子型號(hào)、規(guī)格、走向參照弱電綜合管網(wǎng)施工平面圖。
紅外對(duì)射探測(cè)器主要安裝在智能化小區(qū)地圍墻或柵欄上,我們?cè)诎惭b紅外對(duì)射探測(cè)器前應(yīng)注意以下幾點(diǎn):
(1) 紅外對(duì)射探測(cè)器管線(xiàn)是否到位;
(2)對(duì)每對(duì)紅外探測(cè)器逐一進(jìn)行檢查、測(cè)試,各項(xiàng)技術(shù)指標(biāo)是否符合要求;
(3)小區(qū)圍墻及柵欄是否完工;
(4)必須對(duì)電纜進(jìn)行通斷及對(duì)地測(cè)試;
(5)線(xiàn)纜標(biāo)記是否清晰、齊全;
(6)按施工圖紙的要求進(jìn)行安裝。
根據(jù)“****”的招標(biāo)要求采用離線(xiàn)式的巡更系統(tǒng)。該巡更方式是加強(qiáng)保安防范,督促保安員盡忠職守的一種有力手段。離線(xiàn)式巡更管理系統(tǒng)的采用,一方面能杜絕保安巡視人員不稱(chēng)職現(xiàn)象,同時(shí)能有力地將一些事故案情隱患消滅于未然。
系統(tǒng)可配合用戶(hù)實(shí)際設(shè)定班次、每班始末時(shí)間并可隨時(shí)更改,可任意刪減、變更人員名字及巡更點(diǎn)名稱(chēng)。軟件配有加密狗和密碼多級(jí)權(quán)限,巡更輸入數(shù)據(jù)不可更改,有良好的安全保密性。
1、實(shí)現(xiàn)巡更路線(xiàn)的設(shè)定、修改;
2、實(shí)現(xiàn)巡更時(shí)間的設(shè)定、修改;
3、在重要部位及巡更路線(xiàn)上安裝巡更信息點(diǎn);
4、中心可查閱、打印各巡更人員的到位時(shí)間及工作情況;
本系統(tǒng)布點(diǎn)安裝時(shí)必須牢固,并且要求信息數(shù)據(jù)采集方便。安裝高度為1.3m。
對(duì)****小區(qū)內(nèi)給排水系統(tǒng)、照明回路等進(jìn)行工作狀態(tài)的實(shí)時(shí)監(jiān)測(cè)和控制,從而實(shí)現(xiàn)公共設(shè)備的最優(yōu)化管理并降低故障率。
門(mén)禁系統(tǒng)主要由感應(yīng)卡、讀卡器、門(mén)禁控制器及管理中心構(gòu)成。住戶(hù)持卡打卡開(kāi)門(mén),感應(yīng)卡可以通過(guò)設(shè)定多級(jí)密碼來(lái)賦予不同的權(quán)限,住戶(hù)使用一張卡就可以出入小區(qū)門(mén)。管理中心負(fù)責(zé)感應(yīng)卡的發(fā)放與管理。門(mén)禁系統(tǒng)兼容國(guó)外多種先進(jìn)感應(yīng)卡,是目前兼容性、擴(kuò)展性、實(shí)用性、可靠性最好的集成系統(tǒng)。
? 對(duì)各出入口進(jìn)行人員出入控制;
? 如遇丟失,及時(shí)向中心掛失,則可有效控制掛失卡進(jìn)入小區(qū),解掛實(shí)時(shí)生效,掛失卡打卡不開(kāi)門(mén);
? 所有讀卡資料均有電腦記錄,便于在發(fā)生事故后及時(shí)查詢(xún);
? 任何警報(bào)發(fā)生或指定狀態(tài)改變時(shí),自動(dòng)執(zhí)行一連串的順序控制指令;
? 具有實(shí)時(shí)監(jiān)控功能,即門(mén)戶(hù)的狀態(tài)和行為都可實(shí)時(shí)反映在控制室的電腦中,如門(mén)打開(kāi)/關(guān)閉,哪個(gè)人、什么時(shí)間、什么地點(diǎn)等。門(mén)開(kāi)時(shí)間超過(guò)設(shè)定值時(shí),系統(tǒng)會(huì)報(bào)警;
? 系統(tǒng)軟件針對(duì)不同級(jí)別的操作人員分配多種級(jí)別的操作權(quán)限,輸入不同的密碼可進(jìn)入不同的控制截面。操作員依據(jù)自己的操作權(quán)限在中心的電腦上進(jìn)行各種設(shè)定,如開(kāi)門(mén)/關(guān)門(mén),查看某一被控區(qū)域門(mén)態(tài)情況,授權(quán)卡或刪除卡等;
讀卡器、電磁鎖、均各暗敷一根PVC20管至管理中心門(mén)禁控制器,讀卡器至門(mén)禁控制器穿RVV6×0.5、電磁鎖至門(mén)禁控制器均穿RVV2×0.5,聯(lián)網(wǎng)線(xiàn)采用RVVS4*1.0。管子型號(hào)、規(guī)格、走向參照以后弱電綜合管網(wǎng)施工平面圖。
我們?cè)诎惭b門(mén)禁管理系統(tǒng)設(shè)備前應(yīng)注意以下幾點(diǎn):
? 管線(xiàn)是否到位;
? 線(xiàn)纜標(biāo)記清晰、齊全;
? 對(duì)各線(xiàn)纜進(jìn)行通斷及對(duì)地測(cè)試;
? 對(duì)設(shè)備逐一進(jìn)行檢查、測(cè)試,各項(xiàng)技術(shù)指標(biāo)是否符合技術(shù)要求;
? 按施工圖紙的要求進(jìn)行安裝。
“****”地下停車(chē)場(chǎng)管理系統(tǒng)的設(shè)計(jì)的目的一是為了方便住戶(hù)安全駕車(chē)出入所有小區(qū)出入口及地下停車(chē)場(chǎng),體現(xiàn)小區(qū)物業(yè)管理的人性化;二是減少停車(chē)場(chǎng)的物業(yè)管理人員,提高工作效率;三是提升小區(qū)物業(yè)管理形象。系統(tǒng)以住戶(hù)能安全方便的駕車(chē)進(jìn)出停車(chē)場(chǎng)及統(tǒng)一、高效的進(jìn)行車(chē)輛管理為終極目標(biāo)。
對(duì)于固定車(chē)主來(lái)講:車(chē)主先到系統(tǒng)控制中心電腦處登記,把車(chē)號(hào)、車(chē)型、顏色、駕駛?cè)藛T的姓名、行駛證號(hào)碼等輸入電腦,并領(lǐng)取一卡通卡片。
車(chē)駛至出入口時(shí),住戶(hù)停車(chē)刷卡,控制器接受到信號(hào)后,發(fā)送信息給控制器開(kāi)啟道閘。
對(duì)于臨時(shí)車(chē)主來(lái)講:車(chē)主將車(chē)開(kāi)至入口處時(shí),從自動(dòng)吐卡機(jī)領(lǐng)取臨時(shí)卡,訪客刷卡開(kāi)閘,駛出時(shí)刷卡開(kāi)閘后,向管理員上繳卡片同時(shí)計(jì)算機(jī)自動(dòng)列出停車(chē)信息。
系統(tǒng)聯(lián)網(wǎng)(從每個(gè)道閘布線(xiàn)至智能化管理中心),可以實(shí)時(shí)查詢(xún)到業(yè)主開(kāi)車(chē)進(jìn)出的時(shí)間及車(chē)牌號(hào)碼等信息。
從智能化管理中心暗敷一根G管(按圖紙要求)至室外就近電信井,然后沿此弱電電信井暗敷至收費(fèi)亭,穿一根RVVS4×1.0線(xiàn)+RVVP2×1.0,管子型號(hào)、規(guī)格、走向參照以后弱電綜合管網(wǎng)施工平面圖。
我們?cè)诎惭b停車(chē)場(chǎng)管理系統(tǒng)設(shè)備前應(yīng)注意以下幾點(diǎn):
? 管線(xiàn)是否到位;
? 線(xiàn)纜標(biāo)記清晰、齊全;
? 對(duì)各線(xiàn)纜進(jìn)行通斷及對(duì)地測(cè)試;
? 對(duì)設(shè)備逐一進(jìn)行檢查、測(cè)試,各項(xiàng)技術(shù)指標(biāo)是否符合技術(shù)要求;
? 按施工圖紙的要求進(jìn)行安裝。
在小區(qū)廣場(chǎng)、地下停車(chē)場(chǎng)等處設(shè)置音箱。由智能管理中心集中控制,可在節(jié)假日、每日早晚及特定時(shí)間播放音樂(lè),也可通過(guò)遍布于小區(qū)內(nèi)的音箱播放一些公共知識(shí)、科普知識(shí)、娛樂(lè)節(jié)目、購(gòu)物指南等。同時(shí),在發(fā)生緊急事件,如建筑物內(nèi)一旦發(fā)生火災(zāi)或其它意外事故時(shí)可作為緊急廣播強(qiáng)制切入使用。
(1)平時(shí)播放音樂(lè)節(jié)目,在特定分區(qū)可插入業(yè)務(wù)廣播、會(huì)議廣播和通知等。
(2)當(dāng)火災(zāi)及其它緊急事件發(fā)生時(shí),可切換至火災(zāi)報(bào)警廣播或緊急廣播。
從智能化管理中心敷設(shè)一根RVV2*1.5線(xiàn)至現(xiàn)場(chǎng)草坪音箱以及吸頂喇叭,音源點(diǎn)線(xiàn)采用并接的方式連接,樓層的吸頂喇叭引PVC20管至橋架即可,音源點(diǎn)線(xiàn)從智能化管理中心用一根SC25管暗敷至室外就近電信井,然后沿此電信井暗敷至現(xiàn)場(chǎng),管子型號(hào)、規(guī)格、走向參照弱電管網(wǎng)綜合平面施工圖。
我們?cè)诎惭b小區(qū)背景音樂(lè)系統(tǒng)設(shè)備前應(yīng)注意以下幾點(diǎn):
(1)現(xiàn)場(chǎng)音箱管線(xiàn)是否到位;
(2)對(duì)系統(tǒng)各設(shè)備逐一進(jìn)行檢查、測(cè)試,各項(xiàng)技術(shù)指標(biāo)是否符合要求;
(3)必須對(duì)電纜通斷及對(duì)地測(cè)試;
(4)線(xiàn)纜標(biāo)記是否清晰、齊全;
(5)小區(qū)草坪是否鋪設(shè)完工,各棟樓墻壁是否粉刷完畢;
(6)按施工圖紙的要求進(jìn)行安裝。
****智能化小區(qū)物業(yè)管理過(guò)程中需要及時(shí)向小區(qū)居民發(fā)布小區(qū)物業(yè)管理信息,這就需要一套大屏幕顯示系統(tǒng),電子大屏幕顯示系統(tǒng)作為一套工程化、系統(tǒng)化的高技術(shù)產(chǎn)品,它包括顯示屏控制、接口計(jì)算機(jī)及外圍設(shè)備,多種信號(hào)獲取手段和完善的軟件環(huán)境等,能實(shí)現(xiàn)視頻、聲音、新聞及其它信息的接收、存儲(chǔ)、管理和最終的顯示、播放,是一種全新戶(hù)外傳播媒體。
(1)顯示屏采用模塊化的設(shè)計(jì),整個(gè)屏幕由多個(gè)模塊拼裝而成,屏幕大小設(shè)有限制,可根據(jù)客戶(hù)需要任意定制。
(2)室外顯示屏由于采用超高亮度LED發(fā)光管,屏幕亮度高,顯示內(nèi)容在陽(yáng)光下清晰可見(jiàn)。
(3)多色、多灰度級(jí),色彩鮮艷均勻,灰度級(jí)為16級(jí)或64級(jí),整屏亮度可根據(jù)外界光線(xiàn)強(qiáng)弱自動(dòng)或人工選擇,通常有四級(jí)。
(4)表現(xiàn)形式豐富,可播放視頻、圖像、文體、二維/三維動(dòng)畫(huà)和聲音,在軟件支持下,可分別或迭加播放,能實(shí)現(xiàn)多種顯示效果。
(5)最優(yōu)化的結(jié)構(gòu)設(shè)計(jì),使系統(tǒng)安裝簡(jiǎn)便,防雨抗風(fēng)性能較好。
(6)完善獨(dú)到的工藝措施,可大大延長(zhǎng)使用壽命。
由于大屏距離管理中心距離較遠(yuǎn),為達(dá)到招標(biāo)文件對(duì)傳輸距離的要求,從智能化管理中心暗敷一根PE32至就近電信井,然后沿此電信井暗敷至現(xiàn)場(chǎng)大顯示屏點(diǎn)。管子型號(hào)、規(guī)格走向參照弱電管線(xiàn)綜合施工平面圖。
我們?cè)诎惭b小區(qū)電子大屏幕顯示系統(tǒng)設(shè)備前應(yīng)注意以下幾點(diǎn):
(1)管線(xiàn)是否到位;
(2)線(xiàn)纜標(biāo)記清晰、齊全;
(3)對(duì)各線(xiàn)纜進(jìn)行通斷及對(duì)地測(cè)試;
(4)對(duì)設(shè)備逐一進(jìn)行檢查、測(cè)試,各項(xiàng)技術(shù)指標(biāo)是否符合技術(shù)要求;
(5)按施工圖紙的要求進(jìn)行安裝。
一、 中心機(jī)房施工重點(diǎn)考慮屏幕墻、操作臺(tái)及設(shè)備布置。
二、 考慮防雷及接地裝置。
三、 地板采用防靜電地板。
四、 具體詳細(xì)方案,工程開(kāi)工后及時(shí)以分項(xiàng)工程施工方案報(bào)送。
五、 附屏幕墻、操作臺(tái)效果圖(見(jiàn)下頁(yè))。
其余系統(tǒng)按設(shè)計(jì)方案及施工圖要求精心施工。
屏幕墻
操作臺(tái)
投標(biāo)人名稱(chēng)(公章):****實(shí)業(yè)有限公司
授權(quán)代表簽字:
日期:2005年6月26日
聯(lián)系客服